The TurnaSure DTI Why use TurnaSure DTIs Bolting Applications TurnaSure Projects Research on TurnaSure DTIs Bolting Resources Buying TurnaSure DTIs Contact TurnaSure About TurnaSure Thank You TurnAnut

Research and Reports on DTIs and their use, including TurnaSure DTIs

direct tension indicator research

Tests for stress relaxation over time

1963 to 1971. Sheffield University, Sheffield, England.
bolting technology reports

Fatigue tests on DTIs

1960s Research conducted by British Welding Research Institute, Abington Hall, Cambridge, England.
direct tension indicator reports

Load Indicating Washers-load/gap relationship on unloading and loading

1960s report from Cooper & Turner Ltd. Sheffield, England.
bolting technology tightening reports

Comparison of Tightening Methods of HSFG Bolts

Time trials comparing DTIs with other methods conducted by W.S. Atkins & Partners, Consulting Engineers, P.A. Management Consultants, British Steel, London, England, August 1970.
DTI boltign technology

DTI Case History- DTIs Save More the $150,000

Study on DTI use on Power Plant in Nebraska by Bethlehem Steel, Pennsylvania, USA. Dec 1981.
Bolting technology bolt relaxation

Study discussing influence of load-indicating washers on bolt relaxation in joints subject to high prying forces

Concludes DTIs are a benefit by Dr. J.O. Surtees and M.E. Ibrahim, Leeds University, Yorkshire, England, Published in Civil Engineering Magazine, April 1982.
bolting technology fasteners bolts

Transverse Vibration Loosening Characteristics of High Strength Fastened Joints using DTIs

SPS Contract Research, Jenkintown, Pennsylvania, USA. July 1998.
tension control reports

Study on full flattening of Direct Tension Indicators in Shear Connections

by Prof Edwin R. Schmeckpeper, Prof. Richard J. Nielsen, and Guy Gentry, Department of Civil Engineering, University of Idaho. USA. Concludes full flattening of DTIs had no detrimental affect. Published in Engineering Journal of American Institute of Steel Construction. First Quarter 1999.
bolting technology bolt tension

Impact of Variable Lubricity on Type 325 Structural DTIs

Study showing no change to the new TurnaSure DTIs performance, dry, oiled, or rusty, by Laboratory Testing Inc, Hatfield, Pennsylvania, USA 2000.
DTI bolt tension

Test Report for Accelerated Aging of Weathering Steel Joint using TurnaSure Weathering Steel 7/8" -3 type 325 DTIs

Study concludes DTI prevented rusting inside bolts assembled for unpainted bridges conducted by KTA-Tator, Inc, Pittsburgh, Pennsylvania. USA. Feb 2002.
DTI bolting technology

New Generation Direct Tension Indicators

Article in New Steel Construction magazine, UK describes development of new generation DTIs in USA. Jan-Feb 2004 issue, by Roger Reed, Technical Manager of Thomas William Lench Ltd.